Docsity
Docsity

Prepare-se para as provas
Prepare-se para as provas

Estude fácil! Tem muito documento disponível na Docsity


Ganhe pontos para baixar
Ganhe pontos para baixar

Ganhe pontos ajudando outros esrudantes ou compre um plano Premium


Guias e Dicas
Guias e Dicas

??tc605tc805tc905l????, Notas de estudo de Cultura

EstaçãoTotal TC605l

Tipologia: Notas de estudo

2014

Compartilhado em 30/11/2014

netotop-2
netotop-2 🇧🇷

4.5

(2)

3 documentos

1 / 162

Toggle sidebar

Esta página não é visível na pré-visualização

Não perca as partes importantes!

bg1
TC605/TC805/TC905/L
English
Electronic total station
USER MANUAL
605Z01
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff
pf12
pf13
pf14
pf15
pf16
pf17
pf18
pf19
pf1a
pf1b
pf1c
pf1d
pf1e
pf1f
pf20
pf21
pf22
pf23
pf24
pf25
pf26
pf27
pf28
pf29
pf2a
pf2b
pf2c
pf2d
pf2e
pf2f
pf30
pf31
pf32
pf33
pf34
pf35
pf36
pf37
pf38
pf39
pf3a
pf3b
pf3c
pf3d
pf3e
pf3f
pf40
pf41
pf42
pf43
pf44
pf45
pf46
pf47
pf48
pf49
pf4a
pf4b
pf4c
pf4d
pf4e
pf4f
pf50
pf51
pf52
pf53
pf54
pf55
pf56
pf57
pf58
pf59
pf5a
pf5b
pf5c
pf5d
pf5e
pf5f
pf60
pf61
pf62
pf63
pf64

Pré-visualização parcial do texto

Baixe ??tc605tc805tc905l???? e outras Notas de estudo em PDF para Cultura, somente na Docsity!

TC605/TC805/TC905/L

English

Electronic total station

USER MANUAL

605Z

2 TC605/TC805/TC905/L-1.1.1en © Leica

Thank you for purchasing this Leica Total Station.

This manual contains important safety directions (refer to section "Safety directions") as well as instructions for setting up the instrument and operating it. Please read carefully through the User Manual to achieve maximum satisfaction.

4 TC605/TC805/TC905/L-1.1.1en © Leica

The symbols used in this User Manual have the following meanings:

DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

WARNING:

Indicates a potentially hazardous situation or an unintended use which, if not avoided, could result in death or serious injury.

CAUTION:

Indicates a potentially hazardous situation or an unintended use which, if not avoided, may result in minor or moderate injury and / or appreciable material, financial and environmental damage.

Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner.

Symbols used in this manual

Contents

  • © Leica TC605/TC805/TC905/L-1.1.1en
    • Introduction
      • Applicability
      • Important parts
    • Set-up, getting started
      • Unpacking
      • Charging battery
      • Set-up
        • Tribrach with optical plummet
        • Tribrach without optical plummet
        • Instrument with laser plummet
      • Level instrument with the electronic level
    • Operating concept
      • Settings, first steps
      • Units in this manual
      • Display and keyboard
        • Fixed keys
        • Function keys
        • Control keys
        • Input keys
      • Inputs
        • Numeric / alphanumeric entry mode
        • Entering reflector height
        • General information
      • Menu tree (main menu)
      • Menu tree (configuration)
      • Menu tree (programs)
      • Main menu
    • Measure and record
      • Display symbols
      • Pointing and distance measurement
        • Example: for offset or hidden points
      • Tracking mode
      • Display of recorded measurements
    • Measure and record with coding
    • Coding
      • Input a new code line to the code list
      • Function "Quick-Code"
      • Simple code input during measurements
      • Additional entries to selected code
        • Recording codes
      • Searching for codes using wildcards
  • User Programs 6 TC605/TC805/TC905/L-1.1.1en © Leica
    • Introduction
    • Point search in programs
    • Set Job
    • (Set Station) Set station coordinates and Orientation
      • Orientation of horizontal circle
    • Free Station
    • Setting out (Setout)
    • Tie Distance (Missing line)
    • Area computation (Calc Area)
    • Rapid measurement and recording (Rapid Meas)
    • Reference Line (Ref. Line)
  • Settings
    • Entering point number and reflector height
    • Setting the horizontal circle (Hz)
      • 1st variant
      • 2nd variant
    • Setting the display mask (DSP)
  • Data management (DATA MANAGER)
    • Input of coordinates and codes (INPUT)
      • Coordinate entry (COORDS)
      • Code input (CODES)
    • recordings (FIND) Searching for point numbers and multiple
      • point number Searching for several data blocks with the same
    • Display of stored data (VIEW)
    • (DELETE PNT) Delete measurements, coordinates and codes
    • coordinates and codes (DELETE ALL) Delete the complete range of measurements,
  • EDM Configuration (EDM CONF)
      1. EDM mode
      1. EGL (Guide Light)
      1. INTENS
      1. RETTAP
  • Testing the instrument
    • Battery and instrument temperature
    • EDM Signal (INTENSITY)
  • Configuration (CONFIG MENU)
    • Distance corrections
    • Display contrast (CONTRA)
    • Data and recording parameter (REC DATA)
  • © Leica TC605/TC805/TC905/L-1.1.1en - Selecting units (UNITS) - Setting time and date (TIME/DATE) - Automatic switch-off (ON/OFF)
    • TCTOOLS
    • Other data formats
    • PC/Datalogger Communication TC605/TC805/TC905/L and
      • Set a point number
      • Set station coordinates
      • Set orientation
      • Setting-out
    • Checking and adjusting
      • Determine instrument errors (CALIB)
        • Vertical index error
        • Line-of-sight error (Hz-collimation)
      • Tripod
      • Circular level
        • Circular level on the tribrach
      • Optical plummet
      • Laser plummet
    • Care and transport
    • Battery charging
      • Battery chargers GKL22 and GKL23
      • Battery chargers GKL12 and GKL14
    • Safety directions
      • Intended use of instrument
      • Limits of use
      • Responsibilities
      • Hazards of use
      • Laser classification
        • Integrated distancer (EDM)
        • Guide Light EGL
        • (optional for TC805/TC905/L series)
        • Laser plummet
      • Electromagnetic acceptability
      • FCC statement (applicable in U.S.)
        • Product labeling
    • Error reports and warnings
    • Technical data
    • Index

8 TC605/TC805/TC905/L-1.1.1en © Leica

Introduction

The TC605/TC805/TC905/L is particularly suitable for engineering, building and construction surveys with a focus on setting outs, volume determinations and tacheometry surveys. Fast and easy coding facilities are provided. The accuracy of angle-measuring, and the range of its EDM module, are matched to one another. The measured data can be stored in the internal memory or can be output individually via serial interface to an external recorder.

Applicability This manual applies to the following types of total stations:

  • TC605, TC605L
  • TC805, TC805L
  • TC905, TC905L

Differences between the three versions TC605/TC805/ TC905/L are clearly set out and assigned. General text applies to all versions.

10 TC605/TC805/TC905/L-1.1.1en © Leica

TC805/L

605Z

1 Foot screw 2 Keyboard 3 Display 4 Focusing 5 Carrying handle 6 EDM, Telescope 7 Battery

8 Vertical drive 9 Horizontal drive 10 Serial Interface RS- 11 Circular level 12 Optical sight 13 EGL1 (optional)

12 13^745

© Leica TC605/TC805/TC905/L-1.1.1en 11

TC905/L

605Z

1 Foot screw 2 Keyboard 3 Display 4 Focusing 5 Carrying handle 6 EDM, Telescope 7 Battery

8 Vertical drive 9 Horizontal drive 10 Serial Interface RS- 11 Circular level 12 Optical sight 13 EGL1 (optional)

© Leica TC605/TC805/TC905/L-1.1.1en 13

Charge batteries using GKL12, GKL14, GKL22 or GKL23. For more information about charging batteries refer to chapter "Battery charging".

Charging battery

GEB

Charging time: Internal battery: GEB77 1.0 hours External batteries: GEB70 1.5 hours GEB71 5.0 hours

(Refer also to chapter "Technical Data")

GEB

Å Ç ã / å É

GKL23 (ã) GKL23-1 (å)

ã Version for 230V mains å Version for 115V mains

605Z 605Z

605Z

WARNING:

The battery chargers are intended for indoor use. Only use a battery charger in a dry place, never outdoors.

14 TC605/TC805/TC905/L-1.1.1en © Leica

Set-up

Set-up TC605/TC805/ TC905 with tribrach GDF 22 and tripod GST

5/8" thread

GST

GDF 22

605Z

605Z

605Z

Tribrach with optical plummet

16 TC605/TC805/TC905/L-1.1.1en © Leica

Instrument with laser plummet

Switch off plummet and quit display.

The laser plummet is activated in the measuring display. The instrument can be levelled-up using the electronic level.

Press (for about 2 seconds) until the following display appears. The laser plummet is switched on (red spot on ground) and the electronic level is shown.

tripod

tribrach

5/8"-thread

PLUMMET ON:

605Z

605Z

605Z

or

© Leica TC605/TC805/TC905/L-1.1.1en 17

Level instrument with

the electronic level

Foot screws for levelling-up

◊ MENU 1.SET HZ ‡ ‡2.LEVEL ‡ 3.DATA MANAGER ‡

Perfect levelling-up

LEVEL:

Insufficient levelling-up

The TC605/TC805/TC905/L unit is correctly levelled- up when the triangles are visible only or markers are displayed between the triangles.

LEVEL:

605Z

© Leica TC605/TC805/TC905/L-1.1.1en 19

Display and keyboard

The four colour groupings for the keys are: Grey: Fixed keys Orange: Programs and functions Green: Control keys Yellow: Input keys

The display and the keyboard are divided into specific areas, making the layout clear and the operational procedure easy to learn.

Dialog area

Heading

Display, max. 4x16 characters

Control keys

Input keys

605Z

◊ MENU 1.SET HZ ‡ ‡2.LEVEL ‡ 3.DATA MANAGER ‡

20 TC605/TC805/TC905/L-1.1.1en © Leica

Fixed keys

Turns the instrument ON.

Distance is measured and current measured values are stored.

Distance is measured and values are displayed, but not stored.

Recording measurements (as displayed).

Access coding.

Changes display masks.

Switches on/off display illumination. Switches on the laser plummet (if pressed for about 2 seconds).

Entering point numbers. Switches between numbers and characters during input of point numbers and coding (assignment of to

).

Turns the instrument OFF.

Calls up the on board applications.

Calls up the main menu (short press). Calls up the configurations menu: long press (about 2 seconds).

Function keys