Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

Two Story Residential Building, Study notes of Engineering management

Unfinished CAD file of Two story reisdential building

Typology: Study notes

2024/2025

Uploaded on 04/20/2025

mark-rafael-canlas
mark-rafael-canlas 🇵🇭

5 documents

1 / 1

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
FCO
LAV
WC
KS
FD
BEDROOM
BEDROOM
LIVING AREA
KITCHEN
DINING AREA
T&B
BEDROOM
BALCONY
FCO
WC
FD
T&B
BEDROOM
TERRACE
A
B
C
D
E
12 3 4 12 3 4
A
B
C
D
E
PROPERTY LINE
SANITARY AND STORM DRAINAGE LAYOUT
GROUND FLOOR
SCALE: 1: 75
1
P1
R I G H T O F W A Y
GENERAL NOTES :
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED FLOOR AND WALL OPENINGS.
2. ALL SLOPES FOR HORIZONTAL PIPES SHALL MAINTAIN 1% - 2%, UNLESS OTHERWISE NOTED.
3. ALL FIXTURES SHALL BE VENTED, UNLESS OTHERWISE NOTED.
4. ALL PIPES PASSING THROUGH WALLS, SHALL BE PROTECTED FROM BREAKAGE WITH EMBEDDED METAL PIPE
SLEEVES.
5. ALL PIPES PASSING THROUGH OR UNDER CINDERS OR OTHER CORROSIVE MATERIALS SHALL BE PROTECTED
FROM EXTERNAL CORROSION BY ENCASING SAME WITH POLYETHYLENE SHEATH OR APPROVED EQUAL.
6. ALL OPENINGS INTO A SANITARY DRAINAGE AND VENT SYSTEM, EXCEPT THOSE OPENINGS TO W/C PLUMBING
FIXTURES ARE PROPERLY CONNECTED OR W/C CONSTITUTE VENT TERMINALS, SHALL BE PERMANENTLY
PLUGGED OR CAPPED.
7. ALL WATER PIPES SHALL BE PROVIDED WITH 30 CM PIPE EXTENSION AND CAPPED AT THE END.
8. WORKMANSHIP: THE WORK THROUGHOUT SHALL BE EXECUTED IN THE BEST AND MOST THOROUGH MANNER
KNOWN TO TRADE AND THE SATISFACTION OF THE ARCHITECT AND THE ENGINEER.
9. ALL PIPES SIZES FOR COLD ARE NOMINAL DIAMETERS IN MILLIMETERS.
10. ALL WORKS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF DULY LICENSED SANITARY ENGR. / MASTER
PLUMBER.
SANITARY AND STORM DRAINAGE LAYOUT
SECOND FLOOR
SCALE: 1: 75
2
P1
SANITARY AND STORM DRAINAGE LAYOUT
ROOF
SCALE: 1: 75
3
P1

Partial preview of the text

Download Two Story Residential Building and more Study notes Engineering management in PDF only on Docsity!

FCO

LAV

WC

FD KS

BEDROOM

BEDROOM

LIVING AREA

KITCHEN

DINING AREA

T&B

BEDROOM

BALCONY

FCO WC

FD T&B

BEDROOM

TERRACE

A

B

C

D

E

A

B

C

D

E

PROPERTY LINE

SANITARY AND STORM DRAINAGE LAYOUT

GROUND FLOOR

SCALE: 1: 75

P

R I G H T O F W A Y

GENERAL NOTES :

1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED FLOOR AND WALL OPENINGS.

2. ALL SLOPES FOR HORIZONTAL PIPES SHALL MAINTAIN 1% - 2%, UNLESS OTHERWISE NOTED.

3. ALL FIXTURES SHALL BE VENTED, UNLESS OTHERWISE NOTED.

4. ALL PIPES PASSING THROUGH WALLS, SHALL BE PROTECTED FROM BREAKAGE WITH EMBEDDED METAL PIPE

SLEEVES.

5. ALL PIPES PASSING THROUGH OR UNDER CINDERS OR OTHER CORROSIVE MATERIALS SHALL BE PROTECTED

FROM EXTERNAL CORROSION BY ENCASING SAME WITH POLYETHYLENE SHEATH OR APPROVED EQUAL.

6. ALL OPENINGS INTO A SANITARY DRAINAGE AND VENT SYSTEM, EXCEPT THOSE OPENINGS TO W/C PLUMBING

FIXTURES ARE PROPERLY CONNECTED OR W/C CONSTITUTE VENT TERMINALS, SHALL BE PERMANENTLY

PLUGGED OR CAPPED.

7. ALL WATER PIPES SHALL BE PROVIDED WITH 30 CM PIPE EXTENSION AND CAPPED AT THE END.

8. WORKMANSHIP: THE WORK THROUGHOUT SHALL BE EXECUTED IN THE BEST AND MOST THOROUGH MANNER

KNOWN TO TRADE AND THE SATISFACTION OF THE ARCHITECT AND THE ENGINEER.

9. ALL PIPES SIZES FOR COLD ARE NOMINAL DIAMETERS IN MILLIMETERS.

10. ALL WORKS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF DULY LICENSED SANITARY ENGR. / MASTER

PLUMBER.

SANITARY AND STORM DRAINAGE LAYOUT

SECOND FLOOR

SCALE: 1: 75

P

SANITARY AND STORM DRAINAGE LAYOUT

ROOF

SCALE: 1: 75

P