Electrical Engineering Exercises: Generators, Motors, and Transformers, Exams of Electrical and Electronics Engineering

A series of multiple-choice questions covering fundamental concepts in electrical engineering, specifically focusing on generators, motors, and transformers. The questions test understanding of key principles, calculations, and applications related to these essential components of electrical systems. Suitable for students studying electrical engineering or related fields.

Typology: Exams

2024/2025

Available from 04/05/2025

jason-morales-5
jason-morales-5 🇵🇭

83 documents

1 / 6

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
NAME: DATE:
SUBJECT/SECTION: INSTRUCTOR:
Direction: Write the letter of your answer on the space before the number. (Show your solution).
1. In three phase generator, the windings have voltages generated with an angle out of phase by what angle?
a. 360 degrees b. 180 degrees c. 120 degrees d. 90 degrees
2. In an alternator, the frequency is directly proportional to _____ and _____.
a. Torque and speed c. Poles and Speed
b. Torque and voltage d. Voltage and current
3. A balanced three-phase connection where the phase current is always approximately equal to 57.7% of the line
current.
a. Delta-connected 3 phase system c. Open-Delta connection
b. Star (wye) – connected 3 phase system d. Series-parallel connection
4. For a multiple generating unit to be operated in parallel, the equipment will show when the incoming unit is to be
synchronized with the running unit.
a. Circuit breaker b. Relay c. Synchronoscope d. Oscilloscope
5. This causes the difference between the no-load and full-load voltage of alternator.
a. Voltage regulation c. Voltage drop due to coil reactance
b. Voltage drop due to coil resistance d. Voltage drop due to coil impedance
6. It refers an external dc supply which causes the production of magnetic field in the field windings.
a. Battery b. Commutator c. Exciter d. Generator
7. A power plant station (PPS) wherein the electrical energy is derived from steam.
a.Diesel-Engine PPS c. Geo-thermal PPS
b. Hydro-Electric PPS d. Wind-Turbine PPS
8. In the operation of turbo-generator sets, which situation is applicable?
a. Alternator’s speed is higher than turbine’s speed
b. Alternator’s speed is lower than turbine’s speed
c. Alternator’s speed and turbine’s speed are just the same
d. Alternator’s speed varies as turbine’s speed
9. A type of motor that can be operated in either AC or DC source.
a. Squirrel-cage motor c. Synchronous motor
b. Wound-rotor motor d. Universal motor
10. What specific conditions in the performance characteristic of induction motor when it is designed at low
operating speed?
a. Torque is low c. Low current
b. Torque is high d. Small number of poles
11. This motor can be used and act as a generator where the rotor is applied with dc voltage also known as exciter
while the ac voltage is applied to the stator.
a. Split-phase motor c. Squirrel-cage motor
b. Synchronous motor d. Wound-rotor motor
12. This is the most common type of three-phase motor usually rated above fractional HP size, which is practically
used for ventilating units or water pumps.
a. Wound-rotor motor c. Squirrel-cage motor
b. Synchronous motor d. Capacitor-start motor
13. A type of electric motor that can be used in AC and DC source.
a. Capacitor-start motor c. Split-phase motor
b. Squirrel-cage motor d. Universal motor
14. In a three-phase machine with a given impedance or power triangle, the power factor (PF) can be represented by
what relationship?
a. PF = R / X b. PF = R / Z c. PF = P / S d. both (b) and (c)
15. A 240 volt shunt motor has an armature resistance of 0.38 ohm, what current will flow in the armature when the
back voltage is about 227.5 volts? Assume 2V brush drop.
a. 17.63 A b. 27.63A c. 37.63A d. 47.63A
16. In problem 15, what is the armature-circuit voltage drop?
a. 12.499V b. 10.499V c. 8.499V d. 6.499V
17. A 50-HP, 600V, compound dc motor operates at a speed of 495 RPM at full load. If the flux per pole is
9.1 x 10 6 Maxwell and the armature resistance of 0.015 ohm, how much is the counter EMF? If constant
K = 1.3 x 10 7.
a. 855.58V b. 558.85V c. 885.58V d. 585.85V
18. A 150 KW, 250V, compound dc generator is connected LONG SHUNT. If the shunt filed coil has a resistance of
20 ohms, what amperes will pass in the series filed current?
a. 612.5A b. 512.5A c. 412.5A d. 312.5A
19. A 9HP,460V,3 phase,60Hz, and a 4-pole squirrel cage induction motor operates at full load with an efficiency of
89%, 0.80 PF and 8.5% slip, the full-load speed will be _____
a. 1747RPM b. 1647RPM c. 1547RPM d. 1447RPM
20. In problem (19), how much full-load current is drawn by the motor from the line?
a. 11.83A b. 10.53A c. 9.47A d. 8.43A
21. If a motor is operating at 50 Hertz, what is the specific speed?
a. 1800RPM b. 2000RPM c. 2400RPM d. 3000RPM
pf3
pf4
pf5

Partial preview of the text

Download Electrical Engineering Exercises: Generators, Motors, and Transformers and more Exams Electrical and Electronics Engineering in PDF only on Docsity!

NAME: DATE:

SUBJECT/SECTION: INSTRUCTOR:

Direction : Write the letter of your answer on the space before the number. (Show your solution).

  1. In three phase generator, the windings have voltages generated with an angle out of phase by what angle? a. 360 degrees b. 180 degrees c. 120 degrees d. 90 degrees
  2. In an alternator, the frequency is directly proportional to _____ and _____. a. Torque and speed c. Poles and Speed b. Torque and voltage d. Voltage and current
  3. A balanced three-phase connection where the phase current is always approximately equal to 57.7% of the line current. a. Delta-connected 3 phase system c. Open-Delta connection b. Star (wye) – connected 3 phase system d. Series-parallel connection
  4. For a multiple generating unit to be operated in parallel, the equipment will show when the incoming unit is to be synchronized with the running unit. a. Circuit breaker b. Relay c. Synchronoscope d. Oscilloscope
  5. This causes the difference between the no-load and full-load voltage of alternator. a. Voltage regulation c. Voltage drop due to coil reactance b. Voltage drop due to coil resistance d. Voltage drop due to coil impedance
  6. It refers an external dc supply which causes the production of magnetic field in the field windings. a. Battery b. Commutator c. Exciter d. Generator
  7. A power plant station (PPS) wherein the electrical energy is derived from steam. a.Diesel-Engine PPS c. Geo-thermal PPS b. Hydro-Electric PPS d. Wind-Turbine PPS
  8. In the operation of turbo-generator sets, which situation is applicable? a. Alternator’s speed is higher than turbine’s speed b. Alternator’s speed is lower than turbine’s speed c. Alternator’s speed and turbine’s speed are just the same d. Alternator’s speed varies as turbine’s speed
  9. A type of motor that can be operated in either AC or DC source. a. Squirrel-cage motor c. Synchronous motor b. Wound-rotor motor d. Universal motor
  10. What specific conditions in the performance characteristic of induction motor when it is designed at low operating speed? a. Torque is low c. Low current b. Torque is high d. Small number of poles
  11. This motor can be used and act as a generator where the rotor is applied with dc voltage also known as exciter while the ac voltage is applied to the stator. a. Split-phase motor c. Squirrel-cage motor b. Synchronous motor d. Wound-rotor motor
  12. This is the most common type of three-phase motor usually rated above fractional HP size, which is practically used for ventilating units or water pumps. a. Wound-rotor motor c. Squirrel-cage motor b. Synchronous motor d. Capacitor-start motor
  13. A type of electric motor that can be used in AC and DC source. a. Capacitor-start motor c. Split-phase motor b. Squirrel-cage motor d. Universal motor
  14. In a three-phase machine with a given impedance or power triangle, the power factor (PF) can be represented by what relationship? a. PF = R / X b. PF = R / Z c. PF = P / S d. both (b) and (c)
  15. A 240 volt shunt motor has an armature resistance of 0.38 ohm, what current will flow in the armature when the back voltage is about 227.5 volts? Assume 2V brush drop. a. 17.63 A b. 27.63A c. 37.63A d. 47.63A
  16. In problem 15, what is the armature-circuit voltage drop? a. 12.499V b. 10.499V c. 8.499V d. 6.499V
  17. A 50-HP, 600V, compound dc motor operates at a speed of 495 RPM at full load. If the flux per pole is 9.1 x 10 6 Maxwell and the armature resistance of 0.015 ohm, how much is the counter EMF? If constant K = 1.3 x 10 7. a. 855.58V b. 558.85V c. 885.58V d. 585.85V
  18. A 150 KW, 250V, compound dc generator is connected LONG SHUNT. If the shunt filed coil has a resistance of 20 ohms, what amperes will pass in the series filed current? a. 612.5A b. 512.5A c. 412.5A d. 312.5A
  19. A 9HP,460V,3 phase,60Hz, and a 4-pole squirrel cage induction motor operates at full load with an efficiency of 89%, 0.80 PF and 8.5% slip, the full-load speed will be _____ a. 1747RPM b. 1647RPM c. 1547RPM d. 1447RPM
  20. In problem (19), how much full-load current is drawn by the motor from the line? a. 11.83A b. 10.53A c. 9.47A d. 8.43A
  21. If a motor is operating at 50 Hertz, what is the specific speed? a. 1800RPM b. 2000RPM c. 2400RPM d. 3000RPM
  1. A 3-phase generator is rated at 100KVA has an average PF of 80% at full-load efficiency of 91%, how much reactive power is delivered by generator to the load? a. 60KVAR b. 80KVAR c. 100KVAR d. 125KVAR
  2. In problem (22), what is HP equivalent used by the engine coupled to drive this generator? a. 87.91HP b. 97.91HP c. 107.91HP d. 117.91HP 24 A 15HP, 3-Phase, 4 pole, 60Hertz, Squirrel Cage IM operates at full load with 0.80 PF and 12% slip, then the full-load torque is approximately_____ a. 39.73 lbs-ft b. 49.73 lbs-ft c. 59.73 lbs-ft d. 69.73 lbs-ft
  3. Necessary condition to operate two transformers in parallel a. Operate at the same frequency. b. The voltage ratings must be in proportion to the load shared c. They must have equal KVA ratings d. Their ratio of transformation must be in proportion to the load shared
  4. It is the fall in voltage from no-load condition to rated –load condition and is expressed either in per unit or percentage of the no load voltage at constant primary voltage. a. voltage drop c. voltage regulation b. impedance drop d. voltage sag
  5. Which of the following characteristics is not appropriate for a transformer? a. At with load, it has a variable power factor b. Transform electrical energy from one into another circuits. c. It changes voltage from high to low d. Stationary device in which it is desirable to any frequency.
  6. A termed voltage induced in the coil of transformer or alternator based on Faraday ’s Law of Electromagnetic induction. a. Primary Voltage b. Secondary Voltage c. Counter EMF d. Electromotive Force
  7. In a power transmission system, step-up power transformer is usually used in order to; a. Reduce the voltage from high to low value. b. Increase the current from low to high value. c. Increase the magnitude of voltage at the secondary side d. Reduce the necessary apparent power by the load.
  8. The anti-phase current in transformer is directly proportional to; a. No-load current c. Magnetizing current b. Primary current d. Load current
  9. An induction motor (IM) that is constructed in a manner that the armature coils are housed and is practically in most fractional HP rating. a. Wound rotor IM c. Squirrel cage IM b. Synchronous IM d. Universal mototr
  10. An autotransformer is rated 50 KVA, 13800 / 7200 volts supplying a load of 50KVA at 70.7% lagging PF. What is the transformed power when this transformer is operating at full-load condition? a. 14.88 KW b. 15.65 KW c. 16.91 KW d. 17.63KW
  11. A 50 MVA power transformer has a reactance drop of 2.8% and resistance drop of 1.2% , what percent regulation of this transformer is obtained at 0.8 lagging PF? a. 2.65% b. 3.02% c. 4.06% d. 5.65%
    1. Two distribution transformers are operate in parallel. Unit 1 - 10Kva, 4600:230 V, Ze-s = 0.16 ohm while Unit 2 – 7.5 Kva, 4485:230 V, Ze-s = 0.22 ohm, the circulating current at secondary is approximately___ a. 12.45A b. 15.35 A c. 16.87 A d. 17.30 A
    2. A polarity test is performed upon a 1150/115 – volt transformer. If the applied input voltage is 116V, what would be the subtractive and additive voltage through the voltmeter reading? a. 127.60V & 104.4V c. 146.50V & 103.50V b. 137.50V & 114.5V d. 156.60V & 126.50V
  12. Three 10:1 step-up transformer are connected delta primary and wye secondary for stepping up the 2300-volt three-phase source. What is the secondary line voltage? a. 400V b. 2300V c. 4000V d. 40000V
  13. A single-phase induction motor is designed at 377 radian per sec., what is the specific speed? a. 900 RPM b. 1200 RPM c. 1800 RPM d. 3600 RPM
  14. A 3-phase 40HP,460V,60Hz, Wound Rotor IM has an average efficiency of 83.5% at 0.75 power factor. What is the appropriate AT size of CB and size of wire for this motor? a. 50AT A,#8AWG b. 100AT,#1/0AWG c. 1 50AT,#6AWG d. 250AT, 250MCM
  15. A 10HP, 3-Phase, and a 4-pole SCIM operates at full load with an efficiency of 89% and 80% PF. What would be the operating speed if the slip factor is 0.15? a. 1530 RPM b. 1760 RPM c. 1800 RPM d. 2016 RPM
  16. For problem no.39, what is the rated starting torque of the SCIM if the starting torque is 250% of the rated torque? a. 85.81 lbs-ft b. 34.32 lbs-ft c. 29.17 lbs-ft d. 13.73 lbs-ft
    1. A two-wattmeter is applied at the lines of 3-phase, 220V induction motor. If WMRA and WMRB reads 8.5 Kw and 5.5Kw, determine the operating power factor of this motor? a. 0.9770 b. 0.9375 c. 0.8770 d.0.
  17. What is the average voltage generated in six turn full pitch coil of a 25-cycle alternator if the flux per pole is 7.2 x 10^5 Maxwells?
  1. For generating units to be operated in parallel, the equipment will show when the incoming unit is to be synchronized with the running unit. a. Circuit Breaker b. Relay c. Synchronoscope d. Oscilloscope
  2. This causes the difference between the no-load and full-load voltage of alternator. a. Voltage regulation c. Voltage drop due to coil reactance b. Voltage drop due to coil resistance d. Voltage drop due to coil impedance
  3. It refers an external dc supply which causes the production of magnetic field in the field windings. a. Battery b. Commutator c. Exciter d. Generator
  4. A power plant station (PPS) wherein the electrical energy is derived from steam. b.Diesel-Engine PPS c. Geo-thermal PPS b. Hydro-Electric PPS d. Wind-Turbine PPS
  5. In the operation of turbo-generator sets, which situation is applicable? a. Alternator’s speed is higher than turbine’s speed b. Alternator’s speed is lower than turbine’s speed c. Alternator’s speed and turbine’s speed are just the same d. Alternator’s speed varies as turbine’s speed
  6. A type of motor that can be operated in either AC or DC source. a. Squirrel-cage motor c. Synchronous motor b. Wound-rotor motor d. Universal motor
  7. What specific conditions in the performance characteristic of induction motor when it is designed at low operating speed? a. Torque is low c. Low current b. Torque is high d. Small number of poles
  8. This motor can be used and act as a generator where the rotor is applied with dc voltage also known as exciter while the ac voltage is applied to the stator. a. Split-phase motor c. Squirrel-cage motor b. Synchronous motor d. Wound-rotor motor
  9. This is the most common type of three-phase motor usually rated above fractional HP size, which is practically used for ventilating units or water pumps. a. Wound-rotor motor c. Squirrel-cage motor b. Synchronous motor d. Capacitor-start motor
  10. A type of electric motor that can be used in AC and DC source. a. Capacitor-start motor c. Split-phase motor b. Squirrel-cage motor d. Universal motor
  11. In a three-phase machine with a given impedance or power triangle, the power factor (PF) can be represented by what relationship? a. PF = R / X b. PF = R / Z c. PF = P / S d. both (b) and (c)
  12. A 240 volt shunt motor has an armature resistance of 0.38 ohm, what current will flow in the armature when the back voltage is about 227.5 volts? Assume 2V brush drop. a. 17.63 A b. 27.63A c. 37.63A d. 47.63A
  13. In problem 15, what is the armature-circuit voltage drop? a. 12.499V b. 10.499V c. 8.499V d. 6.499V
  14. A 50-HP, 600V, compound dc motor operates at a speed of 495 RPM at full load. If the flux per pole is 9.1 x 10 6 Maxwell and the armature resistance of 0.015 ohm, how much is the counter EMF? If constant K = 1.3 x 10 7. a. 855.58V b. 558.85V c. 885.58V d. 585.85V
  15. A 150 KW, 250V, compound dc generator is connected LONG SHUNT. If the shunt filed coil has a resistance of 20 ohms, what amperes will pass in the series filed current? a. 612.5A b. 512.5A c. 412.5A d. 312.5A
  16. A 9HP,460V,3 phase,60Hz, and a 4-pole squirrel cage induction motor operates at full load with an efficiency of 89%, 0.80 PF and 8.5% slip, the full-load speed will be _____ a. 1747RPM b. 1647RPM c. 1547RPM d. 1447RPM
  17. In problem (19), how much full-load current is drawn by the motor from the line? a. 11.83A b. 10.53A c. 9.47A d. 8.43A
  18. If a motor is operating at 50 Hertz, what is the specific speed? a. 1800RPM b. 2000RPM c. 2400RPM d. 3000RPM
  19. A 3-phase generator is rated at 100KVA has an average PF of 80% at full-load efficiency of 91%, how much reactive power is delivered by generator to the load? a. 60KVAR b. 80KVAR c. 100KVAR d. 125KVAR
  20. In problem (22), what is HP equivalent used by the engine coupled to drive this generator? a. 87.91HP b. 97.91HP c. 107.91HP d. 117.91HP 24 A 15HP, 3-Phase, 4 pole, 60Hertz, Squirrel Cage IM operates at full load with 0.80 PF and 12% slip, then the full-load torque is approximately_____ a. 39.73 lbs-ft b. 49.73 lbs-ft c. 59.73 lbs-ft d. 69.73 lbs-ft
  21. Necessary condition to operate two transformers in parallel a. Operate at the same frequency. b. The voltage ratings must be in proportion to the load shared d. They must have equal KVA ratings d. Their ratio of transformation must be in proportion to the load shared
  22. It is the fall in voltage from no-load condition to rated –load condition and is expressed either in per unit or percentage of the no load voltage at constant primary voltage.

a. voltage drop c. voltage regulation b. impedance drop d. voltage sag

  1. Which of the following characteristics is not appropriate for a transformer? a. At with load, it has a variable power factor b. Transform electrical energy from one into another circuits. c. It changes voltage from high to low d. Stationary device in which it is desirable to any frequency.
  2. A termed voltage induced in the coil of transformer or alternator based on Faraday ’s Law of Electromagnetic induction. a. Primary Voltage b. Secondary Voltage c. Counter EMF d. Electromotive Force
  3. In a power transmission system, step-up power transformer is usually used in order to; a. Reduce the voltage from high to low value. b. Increase the current from low to high value. c. Increase the magnitude of voltage at the secondary side d. Reduce the necessary apparent power by the load.
  4. The anti-phase current in transformer is directly proportional to; c. No-load current c. Magnetizing current d. Primary current d. Load current
  5. An induction motor (IM) that is constructed in a manner that the armature coils are housed and is practically in most fractional HP rating. c. Wound Rotor IM c. Squirrel Cage IM d. Synchronous IM d. Universal mototr
  6. An autotransformer is rated 50 KVA, 13800 / 7200 volts supplying a load of 50KVA at 70.7% lagging PF. What is the transformed power when this transformer is operating at full-load condition? a. 14.88 KW b. 15.65 KW c. 16.91 KW d. 17.63KW
  7. A 50 MVA power transformer has a reactance drop of 2.8% and resistance drop of 1.2% , what percent regulation of this transformer is obtained at 0.8 lagging PF? a. 2.65% b. 3.02% c. 4.06% d. 5.65%
    1. Two distribution transformers are operate in parallel. Unit 1 - 10Kva, 4600:230 V, Ze-s = 0.16 ohm while Unit 2 – 7.5 Kva, 4485:230 V, Ze-s = 0.22 ohm, the circulating current at secondary is approximately___ a. 12.45A b. 15.35 A c. 16.87 A d. 17.30 A
    2. A polarity test is performed upon a 1150/115 – volt transformer. If the applied input voltage is 116V, what would be the subtractive and additive voltage through the voltmeter reading? a. 127.60V and 104.4V c. 146.50V and 103.50V b. 137.50V and 114.5V d. 156.60V and 126.50V
  8. Three 10:1 step-up transformer are connected delta primary and wye secondary for stepping up the 2300-volt three-phase source. What is the secondary line voltage? a. 400V b. 2,300V c. 4,000V d. 40,000V
  9. A single-phase induction motor is designed at 377 radian per sec., what is the specific speed? a. 900 RPM b. 1200 RPM c. 1800 RPM d. 3600 RPM
  10. A 3-phase 40HP,460V,60Hz, Wound Rotor IM has an average efficiency of 83.5% at 0.75 power factor. What is the appropriate AT size of CB and size of wire for this motor? a. 50AT A b. 100AT c. 150AT,#6AWG d. 250AT,
  11. A 10HP, 3-Phase, and a 4-pole SCIM operates at full load with an efficiency of 89% and 80% PF. What would be the operating speed if the slip factor is 0.15? a. 1530 RPM b. 1760 RPM c. 1800 RPM d. 2016 RPM
  12. For problem no.39, what is the rated starting torque of the SCIM if the starting torque is 250% of the rated torque? a. 85.81 lbs-ft b. 34.32 lbs-ft c. 29.17 lbs-ft d. 13.73 lbs-ft
  13. A two-wattmeter is applied at the lines of 3-phase, 220V induction motor. If WMRA and WMRB reads 8.5 Kw and 5.5Kw, determine the operating power factor of this motor? a. 0.9770 b. 0.9375 c. 0.8770 d.0.
  14. What is the average voltage generated in six turn full pitch coil of a 25-cycle alternator if the flux per pole is 7.2 x 10^5 Maxwells? a. 3.892 V b. 4.225 V c. 4.320 V d.6.109 V
  15. For problem 42, what is the effective voltage? a. 4.320 V b. 4.690 V c. 4.795 V d.6.781 V
  16. A 90-slot stator has a 3-phase 6 – pole whole-coiled winding, each coil of which spans from slot 1 to slot 14, then the pitch factor will be_____ a. 0.978 b. 0.957 c. 0.789 d. 0.
  17. The percent regulation of a 3-phase alternator is 16.304%. If the rated voltage is 460 Volts, what is the zero-load voltage? a. 585 V b. 555 V c. 545 V d. 535 V
  18. In the analysis of short transmission lines which of the following is neglected? a. I 2 R loss b. shunt admittance c. series impedance d. None of these
  19. Line loss of a transmission line for a give power is inversely proportional to; a. line resistance and current c. line impedance and current b. frequency d. supply voltage and power factor