When the Input 2 electrode of a previous channel becomes the Input 1 electrode of the next channel a ____________ montage is designed. correct answers >> Bipolar According to the American Clinical Neurophysiology Society what montages should be performed at a minimum? correct answers >> Longitudinal bipolar, transverse bipolar, and referential Derivation correct answers >> Two electrodes paired in a differential amplifier A1-T3-C3-Cz-C4-T4-A2 is known by two different names. One name is central plane, what is the other? correct answers >> Coronal Which of the following is an advantage of a circumferential montage? correct answers >> Further localize end of chain effects
Typology: Exams
1 / 6
This page cannot be seen from the preview
Don't miss anything!
When the Input 2 electrode of a previous channel becomes the Input 1 electrode of the next channel a ____________ montage is designed. correct answers >> Bipolar According to the American Clinical Neurophysiology Society what montages should be performed at a minimum? correct answers >> Longitudinal bipolar, transverse bipolar, and referential Derivation correct answers >> Two electrodes paired in a differential amplifier
A1-T3-C3-Cz-C4-T4-A2 is known by two different names. One name is central plane, what is the other? correct answers
Coronal Which of the following is an advantage of a circumferential montage? correct answers >> Further localize end of chain effects Which of the following montages should not be used when the patient is asleep? correct answers >> Cz reference Which of the following montages adds all the voltages of each electrode and divides the total by the number of electrodes? correct answers >> Average reference What is another name for a longitudinal bipolar montage? correct answers >> Double banana The incoming (from the patient) signal on a digital EEG instrument is recorded using a _________ reference electrode. correct answers >> System Phase reversal correct answers >> Bipolar montage
reference? correct answers >> Average reference montage When does double phase reversal occur? correct answers
Occurs most frequently in artifact In a bipolar montage input 2 of the previous channel is used as ______ of the next channel? correct answers >> Input 1 Which of the following choices is a name of a common bipolar montage? correct answers >> Longitudinal What is the best way to localize activity in a longitudinal bipolar montage? correct answers >> Identifying phase reversals In a referential montage individual input 1 electrodes are compared to? correct answers >> A common Input 2 electrode A montage that uses an average reference does which of the following? correct answers >> Localizes focal activity
A Laplacian montage uses the mathematical average of how many surrounding electrodes? correct answers >> 4 If focal activity appears to be generalized in a referential montage using a common input 2 electrode, it may indicate that the reference is? correct answers >> Contaminated A transverse bipolar montage displays brain activity from which direction? correct answers >> Left to Right Which is not the name of a plane found within a transverse bipolar montage? correct answers >> Parasaggital When looking at a focus using a referential montage what indicates the location of the focus? correct answers >> Amplitude In a referential montage, the reference electrode is: correct answers >> electrically inactive When is a Cz reference montage problematic? correct answers >> during drowse/ sleep